Tankless Water Heater Size for One Bathroom (Shower + Sink)

By Petrov AndriyUpdated November 15, 2026Guide
We may earn a commission when you buy through links on this page, at no extra cost to you. Learn more.

Part of our Ventilation & Hot Water guides.

Short answer: 18-27 kW. One shower at about 2 GPM plus a sink is the common target. In southern states with warm groundwater, around 18 kW can work; in northern states plan on 24-27 kW.

How the math works

Required power depends on flow (gallons per minute) and temperature rise (desired hot temperature minus incoming water temperature). A shower at 105°F with 50°F incoming water needs a 55°F rise; with 70°F water, only 35°F. That difference changes the size you need by a third or more.

Electrical reality check

Every kW at 240 V draws about 4.2 A. An 18 kW unit draws about 75 A; a 36 kW unit about 150 A spread over multiple breakers. Have an electrician confirm your panel can support it.

Try your own numbers

Use the tankless sizing calculator with your local water temperature.

Worked examples

ScenarioFlowRiseApprox. kW
Florida, 1.8 GPM shower1.8 GPM75°F → 105°F = 30°Fabout 8
Texas, shower + sink2.3 GPM65°F → 105°F = 40°Fabout 13.5
Ohio winter, shower + sink2.3 GPM45°F → 105°F = 60°Fabout 20
Minnesota winter, 2.5 GPM shower2.5 GPM38°F → 105°F = 67°Fabout 24.5

Calculated with kW ≈ GPM × rise ÷ 6.83.

Flow rates to use

Many US shower heads are rated at 1.8-2.5 GPM; bathroom faucets about 0.5-1.2 GPM. Check your fixtures' ratings, usually printed on the head.

If it's not quite enough

A low-flow shower head reduces the kW needed. Alternatively, keep an existing tank and use tankless only for a specific bathroom.

Products mentioned
  • VEVOR 18 kW Electric Tankless Water Heater — $268.90View
  • VEVOR 27 kW Tankless Electric Water Heater, LCD Touch — $279.90View
  • VEVOR 13.8 kW Electric Tankless Water Heater — $199.90View

Frequently asked questions

Will a tankless heater work in winter?

Yes, but output drops as incoming water gets colder, so size for winter conditions.

Is propane better for whole-house?

Propane units don't need big electrical service; see electric vs propane tankless.

Is 18 kW enough for one bathroom?

In warm climates often yes; in cold climates you may need 24-27 kW.

What flow rate should I plan for?

About 2-2.5 GPM for a shower plus a sink.

Can I use a low-flow head to reduce size?

Yes; lower flow lowers the required kW.

Where should the unit be installed?

Close to the bathroom to reduce wait time for hot water.